Avery Berkel L126 Calibration

Calibrating an Avery Berkel L126 is a systematic process involving entering a protected mode, setting a zero point, and applying known weights to map the voltage output to weight values. While the process is technically straightforward, the legal requirements for trade use make this a task often best left to certified service providers to ensure compliance with local regulations.

To calibrate the Avery Berkel L126 digital indicator, you must access the internal calibration switch and follow a specific sequence using a certified test weight. Calibration Steps

Access Setup Mode: Use a small screwdriver or pen to press the SW1 button located on the bottom of the scale. The display should show "DIAG" (diagnose).

Enter Calibration Menu: Press the Zero button twice until the display reads "CAL". Confirm this selection by pressing the Test button.

Select Units: Use the red Zero button to cycle through units (e.g., ounces or pounds) until your preferred measurement appears, then select it with the blue Test button.

Confirm Target Weight: The display will show a default weight value (such as 160.1). If this does not match your intended calibration weight, use the Zero button to adjust it and confirm with the Test button.

Set Zero Point: Ensure the scale platform is empty and the display reads "load zero". Press the blue Test button to capture the zero point.

Load Test Weight: The display will prompt you to "load [weight value]" (e.g., "load 10"). Gently place your known calibration weight in the center of the scale and press the Test button again.

Finalize: After a few seconds, the display should show "done". Remove the weight and press the Test button once more to restart the scale in normal weighing mode. Troubleshooting & Accuracy avery berkel l126 calibration

Surface Stability: Always perform calibration on a flat, hard surface like hardwood or concrete to ensure level readings.

Cleanliness: Check that there is no debris on or under the weighing plate, as this can cause inaccurate calibration.

Manuals: For detailed technical specifications or alternative configuration options, you can find various Avery Berkel scale manuals or browse product support documentation directly from the manufacturer.

Avery Berkel L126 is highly regarded as a straightforward, low-cost digital indicator that does not compromise on quality

. It is specifically praised for its durability in harsh industrial environments. Key Performance Highlights Industrial Durability

: It features a pickled and electro-polished stainless steel finish, making it highly hygienic and resistant to corrosion. Waterproof Rating : The indicator is fully waterproof to IP65/66/67 standards

, ideal for wet or harsh environments like food processing, chemicals, and pharmaceuticals. Precision & Reliability : It offers a standard 6000 division performance , ensuring consistent accuracy for basic weighing tasks. Ease of Use

: The design includes large tactile keys that can be operated while wearing gloves, as well as a remote key function for foot or hand switches. Versatility Calibrating an Avery Berkel L126 is a systematic

: It can be linked to a vast range of load cells, bench scales, and platform scales, supporting weight ranges from 10kg up to 1500kg depending on the connected hardware. machinerymasterslive.com Calibration Overview

Calibration for the L126 and similar Avery Berkel indicators typically requires accessing a service mode via a physical switch. Enter Service Mode : Locate and press the SW1 button

(often on the bottom or back) using a small tool; the display should show "DIAG". Access Calibration

: Navigate using the zero and test buttons until "CAL" is displayed. Set Weight Parameters

: Select the unit (e.g., ounces or kilograms) and confirm the calibration weight value. Zero Calibration : Ensure the scale is empty and confirm "load zero". Span Calibration

: Place the required certified weight on the platform and confirm "load [weight]". Completion

: The display will read "DONE" once successful. Restart the scale to return to normal operation. for a certain weight capacity or a link to the full manual

Avery Berkel L126 Stainless platform scale - Machinery Masters For Trade Use: If your L126 is used

Avery Berkel stainless platform scale, weight range 10kg - 1500kg (0.5kgs), platform 1250mm x 1250mm. Durham, United Kingdom. machinerymasterslive.com


For Trade Use: If your L126 is used for trade (charging customers by weight), it is likely a "Legal for Trade" device. In most jurisdictions, only certified technicians with calibrated traceable weights can perform official calibrations. Unauthorized calibration may violate weights and measures laws and result in fines.


It is crucial to distinguish between Calibration Verification (checking) and Calibration Adjustment (changing).

Most retailers can perform a Daily Verification using a legal-for-trade test weight:

Calibration Adjustment (the process described in Part 3) should only be done by a "Weights and Measures Certified" technician or an in-house service department with traceable weights.

There are two main methods for the L126. Method A (Dip Switch) is for older units; Method B (Keypad) is for newer firmware. Try Method B first.

The L126 is a Class III scale. In most jurisdictions, you are legally required to verify calibration every 6 to 12 months. Operating an uncalibrated scale can result in fines from weights and measures authorities.