Drives V15 Hsp47sp10 Download New | Siemens Mc

For engineers maintaining older TIA Portal V15 systems with SINAMICS MC drives, HSP047 SP10 (or its latest compatible version) is a critical download. Always retrieve it via Siemens Industry Support or the TIA Portal built-in package manager to ensure integrity and version compatibility.


To download the Siemens MC Drives V15 HSP47SP10 (Hardware Support Package for SINAMICS firmware version 4.7 SP10), you must access the official Siemens Industry Online Support (SIOS) Download Links SINAMICS Startdrive V15 Support Package

: The primary download for integrating this firmware into TIA Portal V15 can be found at Entry ID 109754382 Alternative Support Page

: Specific details for the firmware version 4.7 SP10 are also available at Entry ID 109757590 General TIA Portal V15 HSPs

: For a complete list of hardware support packages for V15, visit Entry ID 72341852 Installation Requirements & Instructions Prerequisites : You must have Startdrive V15

already installed on your system before you can apply this Support Package. Export Restrictions

: Note that downloading these packages typically requires a registered Siemens account and may be subject to export-controlled Manual Installation Download the file and extract the contents. In TIA Portal, navigate to Options > Support Packages

Select "Add from file system," navigate to your extracted files, and click Automatic Update : You can also use the Totally Integrated Automation UPDATER

tool included with your TIA installation to automatically find and install the latest HSPs. Do you need help troubleshooting

an installation error or verifying if this HSP supports a specific G120 or S120 drive model? Need link for SINAMICS Startdrive V15 Update 4 - SiePortal

To download and install the Siemens MC Drives V15 HSP47SP10 (Hardware Support Package for SINAMICS firmware version 4.7 SP10), you must follow a specific sequence within the TIA Portal environment. This package allows for the configuration of SINAMICS G120 series drives—including

—that are not natively in the TIA Portal V15 hardware catalog 1. Pre-Installation Requirements

Before attempting the download, ensure your system meets these criteria: Base Software: You must have Startdrive V15 (Basic or Advanced) already installed. Export Restrictions: siemens mc drives v15 hsp47sp10 download new

This specific HSP is often subject to export restrictions. You may need a registered Siemens account, and approval can take up to 48 hours. System Integrity: Path names for the download directory must not contain spaces to avoid installation errors. 2. Download Instructions The HSP files are hosted on the Siemens Industry Online Support (SIOS) Primary Source: Access the Startdrive V15 Support Package page File Package: Look for the download titled TIA_Portal_V15_HSP.zip or the restricted version TIA_Portal_V15_HSP_restricted.zip

if you require specific drive support not found in the free package. Alternate for Errors:

If you encounter errors with newer updates, some users have found success by rolling back to Startdrive V15 Update 1 before applying the HSP. Siemens SiePortal 3. Installation Guide Once the files are downloaded and extracted: Open TIA Portal: Launch your existing V15 installation in "Project View". Navigate to Options: Options > Support Packages from the top menu. "Add from file system" and browse to the extracted file in your target directory. Once the file appears in the list, select it and click

. Note that TIA Portal must be closed during the actual installation process. 4. Troubleshooting Common Issues

To download and install the Siemens MC Drives V15 HSP47SP10 (Hardware Support Package for SINAMICS Firmware V4.7 SP10), follow these steps to update your TIA Portal V15 hardware catalog. 1. Download the Support Package The HSP is specifically for the SINAMICS Startdrive V15

environment and is required to configure drives like the G120, G120C, and G110M with firmware version 4.7 SP10. www.industry-mobile-support.siemens-info.com Official Source : Download the package from the Siemens Industry Online Support (SIOS) Specific Entry ID : Use Entry ID for the Startdrive Support Packages. Export Restrictions

: Note that this download is often subject to export restrictions. You may need to log in to your Siemens Industry Mall

account and undergo a manual verification process before the link becomes active. 2. Pre-installation Requirements : You must have Startdrive V15

(or Update 4 for stability) already installed on your system. Extraction : Once downloaded, unzip the file (typically a format) to a local directory on your PC. 3. Installation Guide (Manual Steps)

You can add the HSP directly within the TIA Portal interface: Open TIA Portal V15 and switch to the Project View Go to the top menu and select Options > Support Packages "Add from file system"

Browse to the folder where you unzipped the download, select the HSP file, and click In the list of "Local support packages," find the entry for SINAMICS firmware V4.7 SP10 , check its box, and click Close all TIA Portal instances

: A prompt will appear; you must close the software completely for the installer to finish. Restart TIA Portal For engineers maintaining older TIA Portal V15 systems

: After the installation completes, the new drive firmware will be available in your Hardware Catalog. Why use this HSP?

Installing this package allows you to use new features in firmware V4.7 SP10, such as support for SIMOTICS GP/SD (1FP1) synchronous reluctance motors

with G120 and G110M drives without needing to upgrade your entire TIA Portal version. www.industry-mobile-support.siemens-info.com SINAMICS firmware

files themselves if you also need to update the physical drive hardware?

Firmware V15 for HSP47SP10 should be deployed following strict preparation, verification, and rollback procedures to minimize downtime and ensure system integrity.

If you are struggling with the HSP, note that Siemens recommends using SINAMICS Startdrive for newer projects. Startdrive is a dedicated add-on for TIA Portal that handles drives more comprehensively than an HSP. However, for V15, the HSP remains the standard method.

Step 1: Do Not Unzip Directly Do not double-click the ZIP file. TIA Portal will manage the extraction.

Step 2: Open TIA Portal Version 15 Launch the software without opening any project.

Step 3: Navigate to Support Packages Go to the top menu: Options → Support Packages.

Step 4: Install from File System

Step 5: Select the Package A dialog will appear listing "MC Drives V15" version 47.10. Check the box next to it.

Step 6: Begin Installation Click “Install”. A progress bar will appear. Do not interrupt this process. Installation typically takes 10–20 minutes. To download the Siemens MC Drives V15 HSP47SP10

Step 7: Restart TIA Portal Once the installation completes, a prompt will ask you to restart TIA Portal. Close all projects and restart the software.

In the world of industrial automation, staying current with software versions is not just about having the latest features—it is about maintaining compatibility, security, and operational efficiency. For maintenance engineers and system integrators working within the Siemens TIA Portal ecosystem, the release of specific Hardware Support Packages (HSPs) is a critical event.

Today, we are taking a closer look at the Siemens MC Drives V15 context and the highly specific HSP47SP10 download, explaining what it is, why you need it, and how to install it safely.

For advanced users, Siemens often hosts direct download links via their cache.industry.siemens.com domain. However, these links expire. The safest method is to use the official SIOS search listed above.

First, let’s decode the terminology:

The HSP47SP10 is a cumulative update. It ensures that TIA Portal V15 can communicate with the latest drive firmware versions available at the time of its release, including improved parameter mapping, safety functions, and communication profiles (PROFIdrive, PROFIsafe).

Step 1: Extract the ZIP file to a temporary folder (e.g., C:\Temp\HSP47).

Step 2: Open TIA Portal V15. Do not open any project yet.

Step 3: Navigate to Options > Support Packages.

Step 4: In the "Support Packages" dialog, click the "Install from file system..." (folder icon) button.

Step 5: Browse to your extracted folder and select the .sp or .hsp file (e.g., Siemens_MC_Drives_V15.sp).

Step 6: Confirm the installation. TIA Portal will now add the package to its internal database. This takes 2-5 minutes.

Step 7: After success, close and restart TIA Portal.

Step 8: Open your project. Go to the device view of your CPU. Open the hardware catalog (right side). Under "Drives & Controllers > SINAMICS", you should see the updated devices. If you previously saw a yellow warning icon on a drive, the new HSP should replace it with a green checkmark.