Vijeo Designer Basic 1.3 Download Guide

Schneider Electric has removed Vijeo Designer Basic 1.3 from its main public download portal, but it is still accessible through their Legacy Software Archive for registered users.

Step-by-step:

Before clicking any download link, it is critical to understand what this software is—and what it is not.

Vijeo Designer Basic 1.3 is a scaled-down, freeware version of Schneider Electric’s HMI configuration software. Unlike the commercial "Vijeo Designer" (versions 6.x and 7.x), the Basic edition is designed exclusively for entry-level Magelis HMIs, specifically the Magelis STO and STU series.

Because Vijeo Designer Basic is industrial software owned by Schneider Electric, it must be legally downloaded from their official support portal.

If you are using modern Magelis HMIs (like the Harmony GTO), Schneider Electric recommends upgrading to Vijeo Designer V6.2 or the newer EcoStruxure Machine Expert software, which offers backward compatibility and better support for modern operating systems.


Disclaimer: This content is for informational purposes. Always ensure you are downloading software from authorized sources to maintain system security and comply with software licensing agreements.

Vijeo Designer Basic 1.3: Guide to Download and HMI Configuration

Vijeo Designer Basic 1.3 is a specialized configuration software from Schneider Electric designed for developing and managing Human Machine Interface (HMI) applications. This "Basic" or "Lite" version is specifically tailored for entry-level HMI models, such as the Harmony Easy ET6 and Magelis HMIGXU series, offering a streamlined feature set for small-to-medium industrial automation projects. Key Features of Vijeo Designer Basic 1.3

While it is a simplified version of the full Vijeo Designer suite, version 1.3 provides essential tools for professional HMI design:

Intuitive Interface: Features a drag-and-drop editor with pre-built widgets like gauges, buttons, and graphs for rapid screen creation.

Protocol Support: Includes communication drivers for Modbus, Ethernet/IP, and various Schneider Electric PLCs.

Simulation Mode: Allows users to test and debug HMI projects directly on a PC before deploying them to physical hardware.

Multilingual Support: Supports up to 15 simultaneous languages and 38 different alphabets within a single project.

Data Management: Basic alarm handling and data logging capabilities to monitor industrial processes in real-time. How to Download Vijeo Designer Basic 1.3

To ensure you receive a secure and legal version of the software, always use official Schneider Electric channels: Vijeo Designer Basic HMI Screen Editor (V2.1.1.47) Vijeo Designer Basic 1.3 Download

Vijeo Designer Basic (specifically version 1.3) is a specialized configuration software from Schneider Electric used to program entry-level Human Machine Interface (HMI) panels. Download and Access

You can typically access the installer through the following official channels:

Schneider Electric Software Portal: The primary source for official installers is the Schneider Electric HMI Software Page.

EcoStruxure Machine Expert: Modern versions of Vijeo Designer are often bundled with the EcoStruxure Machine Expert suite. During the 42-day trial, you can access HMI programming features.

Limited/Trial Mode: Even without a full license, the software can be installed in a Limited Edition mode, which allows full configuration but only permits downloading to specific small panels like the HMISTO and HMISTU series. Installation Guide

System Requirements: Ensure you are using a compatible operating system. Vijeo Designer Lite/Basic 1.3 is notably optimized for Windows XP and Windows 7 32-bit; it may not support 64-bit Windows 7 or newer versions without compatibility adjustments.

Run Installer: Locate the .exe file and run it as an administrator.

Choose Mode: During setup, you can select between Trial Mode (full features for 21 days) or Limited Edition (permanent use for small panels only).

License Activation: If you have a license, use the HMI License Manager after installation to enter your Activation ID (formatted as ACT-XXXX-XXXX-XXXX). Key Features & Compatibility

How to install Vijeo Designer as Demo/Trial/Limited Edition mode

To develop a feature in Vijeo Designer Basic 1.3 (or the more recent version 2.1), you typically use the built-in development environment to create graphical objects, variables, and logic scripts. While Vijeo Designer Basic

is a simplified version of the standard software, it still supports core HMI development workflows. Schneider Electric Core Development Workflow Project Setup : Launch the software and right-click in the pane to select "Create New Project" . Define your project name and password if required. Target Configuration

: Select your HMI hardware. Vijeo Designer Basic is specifically designed for the Harmony GXU Variable Declaration

section to define internal and external tags that link your HMI objects to your PLC or controller. Screen Design

Drag and drop objects like switches, lamps, and numeric displays from the Property Inspector to customize the appearance and behavior of each object. Key Features You Can Develop Schneider Electric has removed Vijeo Designer Basic 1

Project conversion from Vijeo Designer to Vijeo Designer Basic

While there isn't a widely known fictional story titled "Vijeo Designer Basic 1.3 Download,"

this specific software version often represents a critical "missing link" for industrial engineers working with legacy Schneider Electric HMI hardware The Engineer's Hunt (A Typical "Story")

The "story" behind this download usually starts in a dusty factory corner. A technician is tasked with updating an old machine running a Magelis GXU

series terminal. They realize their modern software won't talk to the old hardware. The hunt begins: The Compatibility Wall

: Newer versions like Vijeo Designer 6.3 or Basic 2.1 often don't support the specific firmware on older V1.3-era panels. The Legacy Archive : The engineer must scour the Schneider Electric Support

archives to find the exact 1.3 build to avoid "Project Incompatibility" errors. The "Lite" Confusion : Many users mistake Vijeo Designer Basic Vijeo Designer Lite

, which was the earlier name for version 1.3 software used for XBTN/R/RT terminals. Schneider Electric Technical Realities

If you are looking for this software, keep these details in mind: Hardware Lock

: Vijeo Designer Basic is a "simplified" version specifically for entry-level HMIs like the HMIGXU series.

: Version 1.3 is generally not validated for Windows 11; it typically requires Windows 7 or earlier to run reliably. Official Sources : Always prioritize the Schneider Electric Global Download Center

rather than third-party sites to ensure file integrity and security. Schneider Electric Do you need help finding a specific driver compatibility patch for your HMI model?

Project conversion from Vijeo Designer to Vijeo Designer Basic

Vijeo Designer Basic 1.3 is legacy HMI configuration software from Schneider Electric. Because it is an older version, it is primarily available through the official Schneider Electric software archives or legacy support sections. 1. Downloading the Software

To obtain the installer, follow these steps on the official site: Visit the Official Site: Schneider Electric Download Center Before clicking any download link, it is critical

. While this link often defaults to the latest version (e.g., V2.1), you can use the search bar to look for "Vijeo Designer Basic 1.3" or "Legacy Software". Check Software Updates: If you have a later version installed, the Schneider Electric Software Update tool may provide access to specific older versions or patches. Alternative for "Lite" Versions:

If you specifically need the "Lite" variant for smaller HMIs, search for the Vijeo Designer Lite V1.3 package specifically in the support section. Formacionpoliticaisc 2. System Requirements

Vijeo Designer 1.3 was designed for older Windows environments. Ensure your system meets these specifications: Operating System:

Windows XP Professional (SP2 or greater), Windows Vista Business (32-bit), or Windows 7 (32-bit). Processor: Pentium 4 (2 GHz or faster recommended).

1 GB minimum, though 2 GB is recommended for better performance. Disk Space: At least 2 GB of free space. MRO Electric 3. Installation Guide Preparation:

Close all running applications and disable antivirus software temporarily to prevent installation errors. Run Installer: Locate the downloaded

or insert the installation media. If it doesn't auto-run, navigate to the folder and double-click the setup file. License Mode Selection: Limited/Basic Edition:

For use with specific hardware (like HMISTO/HMISTU series), you can often leave the Reference and Serial Number fields to install in a limited functionality mode. Trial Mode: Standard Vijeo Designer usually offers a 21-day or 42-day trial period without a serial number. Fully Licensed: Enter the Reference and Serial Number provided at purchase. Complete Setup:

Choose your installation directory (default is recommended) and follow the wizard to the end. Restart your computer

immediately after the process finishes to update system components. Formacionpoliticaisc 4. Usage and Documentation For help designing your first HMI screen, refer to the Vijeo Designer Design Guide MRO Electric Tutorial

, which covers basic settings, variable creation, and panel design. MRO Electric Are you looking to use this with a specific HMI model , such as the Magelis or Harmony series?


Right-click Vijeo_Designer_Basic_1.3_Setup.exeRun as Administrator.

Because Schneider sometimes retires old freeware, the authorized reseller platform AutomationDirect (for compatible HMIs) and PLCforum.uz (verified user uploads) sometimes host clean copies. However, always verify SHA-256 checksums.

File details to verify after download:

Warning: Avoid third-party “crack” websites or torrents. These often contain malware, ransomware, or corrupted installers. Always download from official or verified industrial automation archives.

Pro Tip: After downloading, verify the file hash (MD5/SHA1) against official Schneider documentation to ensure integrity.