Wella Climazon Millenium Manual (2026)

Adjust the height of the hood using the handle or foot pedal (depending on the specific sub-model) so that it comfortably clears the client's head. Ensure the client is comfortable before lowering the hood.

  • Set Temperature: Select the desired temperature.
  • Set Timer: Turn the timer knob or press the timer buttons to the required duration. The heating elements will activate.
  • Processing: The unit will maintain the climate inside the dome automatically. When the timer expires, an audible signal will sound, and the heating elements will switch off (fans may continue running briefly to cool the unit).
  • | Component | Frequency | Action | | :--- | :--- | :--- | | Outer hood surface | Daily | Wipe with damp cloth and mild detergent. No abrasives. | | Quartz infrared tubes | Weekly | When cool, wipe with dry lint-free cloth. Oils from hands reduce tube life by 40%. | | Swivel joint bearings | Monthly | Apply one drop of silicone lubricant. Do not use WD-40. | | Timer mechanism | Annually | Professional inspection of internal contacts. | | Power cord | Every 6 months | Check for fraying near the strain relief. | wella climazon millenium manual

    Prohibited actions (red box in manual):